    "id": "CSR.10",
    "type": "Field",
    "position": "CSR.10",
    "name": "Patient Study Eligibility Status",
    "length": 250,
    "usage": "C",
    "rpt": "1",
    "dataType": "CE",
    "dataTypeName": "Coded Element",
    "tableId": null,
    "tableName": null,
    "description": "This field indicates whether the patient was an appropriate candidate for the trial. It is important for quality control and data analysis. The code set will vary among clinical trials. An example answer set is: Yes, No, By Approval, Not Assessed, Unknown. This field is required for the patient registration trigger event (C01).",
    "sample": "",
    "fields": [
        {
            "id": "CSR.10.1",
            "type": "Component",
            "position": "CSR.10.1",
            "length": 20,
            "dataType": "ST",
            "dataTypeName": "String Data",
            "usage": "O",
            "rpt": "1",
            "tableId": null,
            "tableName": null,
            "name": "Identifier",
            "description": "Sequence of characters (the code) that uniquely identifies the item being referenced. Different coding schemes will have different elements here."
        },
        {
            "id": "CSR.10.2",
            "type": "Component",
            "position": "CSR.10.2",
            "length": 199,
            "dataType": "ST",
            "dataTypeName": "String Data",
            "usage": "O",
            "rpt": "1",
            "tableId": null,
            "tableName": null,
            "name": "Text",
            "description": "The descriptive or textual name of the identifier, e.g., myocardial infarction or X-ray impression."
        },
        {
            "id": "CSR.10.3",
            "type": "Component",
            "position": "CSR.10.3",
            "length": 20,
            "dataType": "ID",
            "dataTypeName": "Coded values for HL7 tables",
            "usage": "O",
            "rpt": "1",
            "tableId": "0396",
            "tableName": "Coding system",
            "name": "Name Of Coding System",
            "description": "Identifies the coding scheme being used in the identifier component. The combination of the identifier and name of coding system components will be a unique code for a data item. Each system has a unique identifier."
        },
        {
            "id": "CSR.10.4",
            "type": "Component",
            "position": "CSR.10.4",
            "length": 20,
            "dataType": "ST",
            "dataTypeName": "String Data",
            "usage": "O",
            "rpt": "1",
            "tableId": null,
            "tableName": null,
            "name": "Alternate Identifier",
            "description": "An alternate sequence of characters (the code) that uniquely identifies the item being referenced. See usage note in section introduction."
        },
        {
            "id": "CSR.10.5",
            "type": "Component",
            "position": "CSR.10.5",
            "length": 199,
            "dataType": "ST",
            "dataTypeName": "String Data",
            "usage": "O",
            "rpt": "1",
            "tableId": null,
            "tableName": null,
            "name": "Alternate Text",
            "description": "The descriptive or textual name of the alternate identifier. See usage note in section introduction."
        },
        {
            "id": "CSR.10.6",
            "type": "Component",
            "position": "CSR.10.6",
            "length": 20,
            "dataType": "ID",
            "dataTypeName": "Coded values for HL7 tables",
            "usage": "O",
            "rpt": "1",
            "tableId": "0396",
            "tableName": "Coding system",
            "name": "Name Of Alternate Coding System",
            "description": "Identifies the coding scheme being used in the alternate identifier component."
        }
    ]
}